Specifications
TECHNICAL SUPPORT: 1.800.283.5936 (USA) OR 1.801.974.3760
APPENDIX E • SERIAL COMMANDS
96
Ambient Level Adjust
DESCRIPTION:
This command selects/reports the setting of the ambient level.
BINARY FORM DETAILS
COMMAND FORM: <Header><Argument 1>
COMMAND ID: 3
ARGUMENT SIZE: 1 word
ARGUMENT FORM:
Name: Channel Group Value
Size 8 bits 8 bits 16 bits
Type Unsigned integer Unsigned integer Signed Float
Range See Mic Input in Group 3(Mic) -80.0 to 0
Channels (Table 1, p. 93)
Units N/A N/A dB
RETURN VALUES:
Unit always returns the last executed ambient level on selection in the same form as above.
TEXT FORM DETAILS
COMMAND FORM: <DEVICE> AMBLVL <Channel> [Value]
Where:
DEVICE: See General Text command form Description
AMBLVL Text Command
Channel See Mic Input in Group and Channels (Table 1, page 93)
Value
-80.0 to 0 Ambient level in dB
Null return the current level
RETURN VALUES
The command will return the updated condition of ambient level in the same format as the command.
If Command Returns
The ambient level of channel 1 is -50 dB DEVICE AMBLVL 1 -50