Specifications

TECHNICAL SUPPORT: 1.800.283.5936 (USA) OR 1.801.974.3760
APPENDIX E SERIAL COMMANDS
115
Front Panel passcode
DESCRIPTION:
This command sets and reports the current passcode setting for the unit. Each character in the password
represents a button on the front panel. See button assignment table below. When the user is requested to unlock
the front panel, they must press the buttons in the sequence of the stored password.
BUTTON ASSIGNMENT TABLE:
Value Button represented
1 Up arrow button
2 Enter button
3 ESC button
4 Down arrow button
5 Meter button
BINARY FORM DETAILS
COMMAND FORM: <Header><Argument 1><Argument 2>
COMMAND ID: 17
ARGUMENT SIZE: 2 words
ARGUMENT FORM:
Name Char1 Char2 Char3 Char4 Char5 Reserved
Size 8 bits each 24
Type Unsigned Integer — Unsgnd Int
Range 1-4 0
RETURN VALUES:
Unit always returns new value of passcode in the same form as above.
TEXT FORM DETAILS
COMMAND FORM: <DEVICE> FPP <char1> <char2> <char3> <char4> <char5>
Where:
DEVICE: See General Text command form Description
FPP Text Command
char1 - char5
1 – 4 See button assignment table above for description
CLEAR Parameters to clear the passcode
Null parameter to return current passcode
RETURN VALUES
The command returns the current or updated condition of the front panel passcode.
If Command Returns
Front panel passcode is set to UP, UP, DOWN, DOWN, ENTER DEVICE FPP 11442