Specifications

TECHNICAL SUPPORT: 1.800.283.5936 (USA) OR 1.801.974.3760
APPENDIX E SERIAL COMMANDS
130
Level Report Rate
DESCRIPTION:
Sets the level report rate for the unit and activates/deactivates level repeating.
BINARY FORM DETAILS
COMMAND FORM: <Header><Argument 1>
COMMAND ID: 60
ARGUMENT SIZE: 1 word
ARGUMENT FORM:
Name Value
Size 32 bits
Type Unsigned Int
Range 0 to stop reporting but leave statuses set, 1 to stop reporting and clear all report statuses, 50
– 1000ms (one meter (lvl) repeated every 50-1000ms)
RETURN VALUES:
Unit will return the updated state of the last selection in the same form as the command.
TEXT FORM DETAILS
COMMAND FORM DEVICE LVLRRATE [Value]
Where:
DEVICE: See General Text command form Description
LVLRRATE Text Command
Value 0 to stop reporting but leave statuses set, 1 to stop reporting and clear all report statuses, 50
– 1000ms
RETURN VALUES
Unit will return the updated state of the last selection in the same form as the command.
Example
#40 Lvlrrate 100 repeats a meter every 100ms