Specifications
TECHNICAL SUPPORT: 1.800.283.5936 (USA) OR 1.801.974.3760
APPENDIX E • SERIAL COMMANDS
136
Maximum Gain Setting
DESCRIPTION:
This command changes or reports back the maximum gain setting for an input, output or assignable processing
block.
BINARY FORM DETAILS
COMMAND FORM: <Header><Argument 1>
COMMAND ID: 125
ARGUMENT SIZE: 1 word
ARGUMENT FORM:
Name: Channel Group Value
Size 8 bits 8 bits 16 bits
Type Unsigned integer Unsigned integer Signed Float
Range See Group and Channels 1, 2, 3, 5, 7 -65.00–20.00
Unit N/A N/A DB
RETURN VALUES:
Unit will return the updated state of the last selection in the same form as the command.
TEXT FORM DETAILS
COMMAND FORM: DEVICE MAX <Channel> <Group> [Value]
Where:
DEVICE: See General Text command form Description
MAX Text Command
Channel See Group and Channels (Table 1, page 93)
Group I, O, M, P, L
Value
-65.00 – 20.00 Parameter to set the maximum gain setting
Null Parameter to return the current setting
RETURN VALUES
Unit will return the updated state of the last selection in the same form as the command.
If Command Returns
The maximum gain setting on input channel 2 is 10 dB DEVICE MAX 2 I 10