Specifications
TECHNICAL SUPPORT: 1.800.283.5936 (USA) OR 1.801.974.3760
APPENDIX E • SERIAL COMMANDS
147
PA Reference Select
DESCRIPTION:
This command selects/reports which output is used for each mic as a reference for power amp adaptation mode.
There can be only one selection per mixer.
BINARY FORM DETAILS
COMMAND FORM: <Header><Argument 1>
COMMAND ID: 48
ARGUMENT SIZE: 1 word
ARGUMENT FORM:
Name: Channel Group Value
Size 8 bits 8 bits 16 bits
Type Unsigned integer Unsigned integer Unsigned integer
Range See Mic in Group and 2, 8 0; see Group and
Channels (Table 1, (O, E) Channels (p. 93)
page 93) E: see Expansion
Bus Reference
Channels Group
and Channels
(p. 93)
RETURN VALUES:
Unit always returns the last executed REFSEL selection in the same form as above.
TEXT FORM DETAILS
COMMAND FORM: <DEVICE> REFSEL < Reference Channel > < Reference Group > [Channel]
Where:
<DEVICE>: See General Text command form Description
REFSEL Text Command
Channel See Mic in Group and Channels (Table 1, page 93)
Reference Group ‘O’, ‘E’. See Group and Channels (Table 1, page 93)
Reference Value O: see Group and Channels (Table 1, page 93)
E: see Expansion Bus Reference channels in Group and Channels (Table 1,
page 93)
RETURN VALUES
The command will return the updated condition of the REFSEL mode in the same format as the command.
If Command Returns
REFSEL is set for output channel 1 for Mic 1 DEVICE REFSEL 1 O 1