Specifications
TECHNICAL SUPPORT: 1.800.283.5936 (USA) OR 1.801.974.3760
G-WARE SOFTWARE • SECURITY
24
Unit Properties — New Unit/Security Tab
Enter the modem password you wish to use, then select the panel’s time out lock mode and minutes
(how many minutes of standby until the unit locks). The range is from 0-15 minutes; 5 minutes is the
default. If the unit is in the “Lock When Timed Out” mode, the PSR1212’s panel will lock if no panel
buttons are depressed during the designated amount of time. If it is in the “Lock Panel” mode, it is
locked immediately. When locked, the front panel can be accessed only after entering the proper front
panel button sequence (described below) or unlocking the panel using G-Ware.
Next, click any sequence of the five front panel buttons displayed. Your choices will be displayed in the
column on the right. Click Clear if you wish to reset your choices. When you are finished, click OK to
enable your selections.
This completes the initial unit properties configuration. The G-Ware Flow Screen window will now be
displayed (see page 25).
The Baud Rate and Flow Control must be configured from the
front panel of the PSR1212 unit. If you have already done this, these
two parameters will display in the Unit Properties—New Unit/Comm tab
window. See the LCD Menu Tree on page 10 for the location of the
Baud Rate and Flow Control in the LCD menu structure. Set the Serial
Echo (default is On) and Serial Mode (default is Text) you wish to
configure. The Serial Echo feature enables the PSR1212 to echo back
the commands you send over the PSR1212 network. The serial mode
determines the format in which the commands return—text or binary.
Note that the serial echo defaults to Binary when G-Ware is connected
to a unit. It defaults back to Text when G-Ware is disconnected.
If a modem is connected to the PSR1212 unit, select the Use Modem
box and enter the initialization string. Click OK; the PSR1212 will
initialize the modem.
Next, click on the Security tab.