Specifications
TECHNICAL SUPPORT: 1.800.283.5936 (USA) OR 1.801.974.3760
APPLICATION EXAMPLE • HOTEL/CONVENTION CENTER
75
Pin Assignment for Preset 4
Pin Assignment for Preset 5
key differences. For Preset 2, Switch 1 (Preset Mask) is still set to High
because the first partition is still closed. Switch 2, which would be used
for Removable Partition 2, would be controlled through Pin 3. In this
case, it would be set to High because the partition is closed.
Room B uses Microphones 3 and 4, as well as Speaker 2. Set the
appropriate routing parameters in the Preset configuration matrix.
Continue configuring Preset 2 by establishing the Change Preset Label,
Mixer Controls, etc. as desired in the Preset Sidebar window.
Preset 3
Select 3 in the Preset Selection menu.
Preset 3, which is for Room C, requires the Preset Mask Pin 3 to be set
to High, as Partition 2 is closed. Note that Pin 1 and Switch 1 are
irrelevant (and therefore not used) for Preset 3.
Room C uses Microphones 5 and 6, as well as Speaker 3. Set the
appropriate routing parameters in the Preset Configuration matrix.
Continue configuring Preset 3 by establishing the Change Preset Label,
Mixer Controls, etc. as desired in the Preset Sidebar window.
Preset 4
Select 4 in the Preset Selection menu.
For Preset 4, Rooms B and C are combined. In this case, Preset Mask
Pin 1 is set to High because Partition 1 between Rooms A and B is
closed. Pin 3 is set to Low because Partition B is open.
When Rooms B and C are combined, you will want to gate off the mics
in either Room B or C and route one or both of the other two mics to
Speakers 2 and 3. Make the appropriate routing and gating changes in
the Preset configuration matrix to do this. Note that Preset 1 in Room A
is unaffected; an ongoing meeting in that room is not disturbed when
Preset 4 is activated.
Continue configuring Preset 1 by establishing the Change Preset Label,
Mixer Controls, etc. as desired in the Preset Sidebar window.
Preset 5
Select 5 in the Preset Selection menu.
For Preset 5, Rooms A and B are combined. In this case, Preset Mask
Pin 1 is set to Low because Partition 2 between Rooms A and B is open.
Pin 3 is set to High because Partition B is closed.
Pin Assignment for Preset 3