Specifications
TECHNICAL SUPPORT: 1.800.283.5936 (USA) OR 1.801.974.3760
APPENDIX C • CONTROL PANEL INSTALLATION
86
915-155-050 ASSEMBLY, SELECT CONTROL PANEL INCLUDES:
820-155-050 CONTROL PANEL PCB ASSEMBLY W/TWO FOUR-PIN PHOENIX CONNECTORS
740-155-052 CONTROL PANEL MOUNTING BRACKET
625-100-006 ELASTOMER CONDUCTIVE RUBBER SWITCH PADS (4 EACH)
SELECT CONTROL PANEL 910-155-050
460-155-002 WALL ENCLOSURE 2.25 X 3.25 INCHES
681-010-616 SCREWS (2) 6-32 X 1 INCH PPH
740-155-050 FACIA PLATE
460-155-001 FACEPLATE
FLAT HEAD SCREWS (2)
INCLUDED WITH FACEPLATE
673-016-104
CONN TERM BLOCK/
F EURO 4 P
(2 EACH)
VOLUME CONTROL PANEL 910-155-051
FLAT HEAD SCREWS (2)
INCLUDED WITH FACEPLATE
460-155-001 FACEPLATE
740-155-051 FACIA PLATE
915-155-051 ASSEMBLY, VOLUME CONTROL PANEL INCLUDES:
820-155-051 VOLUME CONTROL PANEL PCB ASSEMBLY W/TWO FOUR-PIN PHOENIX CONNECTORS
740-155-052 CONTROL PANEL MOUNTING BRACKET
625-100-006 ELASTOMER CONDUCTIVE RUBBER SWITCH PADS (3 EACH)
460-155-002 WALL ENCLOSURE 2.25 X 3.25
681-010-616 SCREWS
(2) 6-32 X 1 INCH PPH
673-016-104
CONN TERM BLOCK/
F EURO 4 P
(2 EACH)
Figure 4. Select
Control Panel
Assembly
Figure 5. Volume Control
Panel Assembly
Route the other end of the cable through the back of the electrical wall box. Plug the other connector termi-
nator block into either Phoenix connector on the Control Panel, then connect the Cat 5 cable to it, observing
the twisted-pair procedure described previously. Ensure proper wiring; cross connections can cause dam-
age to the PSR1212 unit and Control Panel.
If you are using a second Control Panel, you can connect it to the unused Remote Panel connector on the
PSR1212 or the unused connector on the first Control Panel. You can daisy-chain up to six Control Panels
from each PSR1212 Remote Panel connector. Do not wire more than one Control Panel directly to a
PSR1212 Remote Panel connector; use the daisy-chain method for additional panels. Total Control Panel
system cable run depends on the number of Control Panels used. The distance information in the table
below is based on Cat 5 cable with a nominal resistance of 27 Ohms per 1,000 feet. All distances refer to
total cable runs from a single PSR1212 Remote Panel connector. For information about extending beyond
800 feet (total) with six Control Panels, call Technical Support at 1-800-283-5936 or 1-801-974-3760.
Step 5 As shown in Figures 4 and 5, use the supplied pan-head screws to install the Control Panel PCB
assembly to the electrical wall box.
Step 6 To install the facia plate, position it over the conductive rubber switch pads on the PCB assembly, as
shown in Figures 4 and 5.
Step 7 Mount the faceplate over the rubber switch pads, using the two flat HD screws.
4
3
2
1
4
3
2
1
Gentner Unit Rear Panel
4
3
2
1
4
3
2
1
Control Panel Phoenix Connectors
REAR PANEL A REAR PANEL B
(connector terminator blocks not shown)
Figure 3. RS-485 Phoenix Connector
# of Control Panels Maximum Distance*
1 3,000 ft/914 meters
2 2,500 ft/762 meters
3 1,600 ft/488 meters
4 1,200 ft/366 meters
5 1,000 ft/305 meters
6 800 ft/244 meters