Operation Manual

255
GHOLD – Gate Hold Time Adjust
This command selects/reports the setting of hold time.
Command Form: DEVICE GHOLD <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 3 (M)
Value Unsigned Float 2 0.10 – 8.00
(Null to query in text)
S
GMODE – Gating Mode
This command selects/reports the setting of gating mode.
Command Form: DEVICE GMODE <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 3 (M)
Value Unsigned Integer 2 1 = Auto
2 = Manual On
3 = Manual Off
(Null to query in text)
GOVER – Gating Override
This command selects/reports the setting of gating override.
Command Form: DEVICE GOVER <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 3 (M)
Value Unsigned Integer 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
GPIOSTATUS – General Purpose Status
This command sets the state of a General Purpose Status Pin.
Command Form: DEVICE GPIOSTATUS Pin Port [Value]
Argument Type Size Values Units
Pin Unsigned
Integer
1 1 – 24 (Only user definable status pins.
Port Unsigned
Integer
1 1 – 2
Value Unsigned
Integer
2 0 = High
1 = Low
2 = Toggle
(NULL to query in text)
GRATIO – Gate Ratio Adjust
This command selects/reports the setting of the gate ratio.
Command Form: DEVICE GRATIO <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 3 (M)