XAP Frequently Asked Questions
~
Software/Configuration
~
Echo Cancellation
~
Audio Performance
~
Expansion Bus
~
Firmware
~
Installation
~
Presets
~
Telephone Hybrid
Software/Configuration
What is the correct software program to use with my ClearOne units?
Use G-Ware with the XAP product family and the PSR1212.
Use AP-Ware with the AP product family.
There is no software for the GT1524.
When I open G-Ware, some of the items are not displayed correctly or are grayed out and the
matrix doesn't show any default cross points. If I try to add a cross point, the audio is not routed
there.
You have an improperly installed dcom98 file. Find the dcom98.exe file in your computer (using the
Search feature on your Start menu) and double-click it to begin the dcom98 installation. After the
installation and computer reboot, G-Ware should work correctly.
What does the G-Ware error message "Can't Open Port" mean?
That means your computer COM port is not free or cannot be opened. It does not refer to the XAP unit
COM port. Use a different COM port or make certain another device such as a handheld organizer isn't
still seizing it.
When I try to run G-Ware, why do I get a "No Class Registered Error?"
This error is caused by improper software installation. When using Windows NT, 2000, or XP, you must
log on as the administrator before attempting to install software. To resolve this issue, log on as the
administrator and re-install G-Ware.
Why do the labels in G-Ware look like they are not aligned correctly? Why am I getting a range
error?
Your computer display is set to the Large Fonts setting. Change it to Small Fonts. You do that from the
Windows Control Panel/Display/Settings/Advanced window.
I am unable to establish a serial connection with the XAP/PSR unit when I use G-Ware or
HyperTerminal.
There are three possible solutions.
• The serial port is not properly configured or connected. Check the following items:
~ Baud rate in G-Ware Site Properties window matches the baud rate set in the XAP/PSR unit.
~ Correct COM port on your computer is selected and is available.
~ You are using a pin-to-pin straight through serial cable with all pins connected. If you are
using a cable with only pins 2, 3, and 5 connected, you must turn Flow Control off on the
XAP/PSR unit.
• The unit needs to be power cycled. Unplug the unit and then plug it back in.
•· The unit needs to be reset to the default settings.
Should I set one of my XAP units as a master and the others as a slave?
Not necessarily. Setting a unit as a Master causes it to block audio coming into it from the expansion bus.
In most cases you should have all XAP and PSR units configured as slave units (default) unless you want
a specific unit to break the audio chain throughout your system. Then you would set that unit to Master.