112
Gate Hold Time Adjust
DESCRIPTION:
This command selects/reports the setting of hold time.
RETURN VALUES:
Unit always returns the last executed hold time selection in the same form as above.
TEXT FORM DETAILS
COMMAND FORM: <DEVICE> GHOLD <Channel> [Value]
Where:
DEVICE: See General Text command form Description
GHOLD Text Command
Channel See Mic input in Groups and Channels (Table 1, page 95)
Value
0.10-8.00 select hold time of 0.10 to 8.00 seconds
Null return the current hold time
RETURN VALUES
The command will return the updated condition of the hold time in the same format as the command.
If Command Returns
Hold time is set for 1 second on channel 1 DEVICE GHOLD 1 1.00
Gate Status
DESCRIPTION:
This command reports the gate status of channels 1-8. This command is read only.
RETURN VALUES:
Unit always returns the last executed gate status selection in the same form as above.
TEXT FORM DETAILS
COMMAND FORM <DEVICE> GATE
Where:
DEVICE: See General Text command form Description
GATE Text Command
RETURN VALUES
The command will return the updated condition of the signal presence status of line inputs 9-12 and gate status of
channels 1-8. Represented as a hex number.
If Command Returns
Channels 1 and 2 are gated on DEVICE GATE 03
Channels 1 and 3 are gated on DEVICE GATE 05
Channels 1, 4 and 7 are gated on DEVICE GATE 49