Specifications

TECHNICAL SUPPORT: 1.800.283.5936 (USA) OR 1.801.974.3760
APPENDIX E SERIAL COMMANDS
115
Gating Override
DESCRIPTION:
This command selects/reports the setting of gating override.
RETURN VALUES:
Unit always returns the last executed gating override selection in the same form as above.
TEXT FORM DETAILS
COMMAND FORM: <DEVICE> GOVER <Channel> [Value]
Where:
DEVICE: See General Text command form Description
GOVER Text Command
Channel See Mic Input in Groups and Channels (Table 1, page 95)
Value
0 select gating override to off (does contribute)
1 select gating override to on (does not contribute)
2 toggle gating override
Null return the current mode
RETURN VALUES
The command will return the updated condition of the gating mode in the same format as the command.
If Command Returns
Gating override is set for on for channel 1 DEVICE GOVER 1 1
Label
DESCRIPTION:
This selects/reports the label of the specific channel identified in the unit.
RETURN VALUES:
Unit always returns the label command in the same form as above.
TEXT FORM DETAILS
COMMAND FORM:
<DEVICE> LABEL <Channel><Group>[In/Out String]
Where:
DEVICE: See General Text command form Description
LABEL Text Command
Channel See Groups and Channels (Table 1, page 95)
Group ‘I’, ‘O’, ‘M’, ‘G’, ‘P’, ‘L’, ‘E’, ‘U’, ‘W’, ‘S’, ‘C’
In/Out For Expansion Bus groups specifies input to the matrix or output from matrix. For other
groups this parameter is not used.
String String of up to 20 characters representing the label text. NULL to query and CLEAR to clear
the label.
RETURN VALUES
The command will return the label in the same format as the command.
If Command Returns
The label for input channel 3 is "Gentner Mic" DEVICE LABEL 3 I Gentner Mic
The label for the unit is Room 1 DEVICE LABEL Ø U Room 1