Specifications

TECHNICAL SUPPORT: 1.800.283.5936 (USA) OR 1.801.974.3760
APPENDIX E SERIAL COMMANDS
125
Minimum and Maximum Gain Setting
DESCRIPTION:
This command changes or reports back the minimum and maximum gain setting for an input, output or assignable
processing block.
RETURN VALUES:
Unit will return the updated state of the last selection in the same form as the command.
TEXT FORM DETAILS
COMMAND FORM: DEVICE MINMAX <Channel> <Group> [Minimum Maximum]
Where:
DEVICE: See General Text command form Description
MINMAX Text Command
Channel See Groups and Channels
Group I, O, M, P, L
Minimum
-65.00 20.00 Parameter to set the minimum gain setting
Null Parameter to return the current settings
Maximum
-65.00 20.00 Parameter to set the maximum gain setting
RETURN VALUES
Unit will return the updated state of the last selection in the same form as the command.
If Command Returns
The minimum gain setting on input channel 2 is –10dB and the maximum is 10dB DEVICE MINMAX 2 I –10 10
Modem Initialization String
DESCRIPTION:
This command sets/reports the modem initialization string of the serial port when in modem mode.
RETURN VALUES:
Unit always returns the last executed modem initialization string in the same form as above.
TEXT FORM DETAILS
COMMAND FORM: <DEVICE> MINIT [String]
Where:
DEVICE: See General Text command form Description
MINIT Text Command
String
String =1-80 characters Parameter to select string characters to be sent to the modem when the
unit is initialized
String=CLEAR Parameter to clear the modem initialization string
String =Null Parameter to report the current string
RETURN VALUES
The command will return the updated state in the same form as the command.