Specifications
TECHNICAL SUPPORT: 1.800.283.5936 (USA) OR 1.801.974.3760
APPENDIX E • SERIAL COMMANDS
129
Number of Open Microphones Mode
DESCRIPTION:
This command selects/reports the setting of Number of Open Microphones (NOM) on output channels.
RETURN VALUES:
Unit always returns the last executed NOM selection in the same form as above.
TEXT FORM DETAILS
COMMAND FORM: <DEVICE> NOM <Channel> [Value]
Where:
DEVICE: See General Text command form Description
NOM Text Command
Channel See Output in Groups and Channels (Table 1, page 95)
Value
0 select NOM off
1 select NOM on
2 select NOM to toggle
Null return the current mode
RETURN VALUES
The command will return the updated condition of NOM in the same format as the command.
If Command Returns
NOM is set to be on for output channel 1 DEVICE NOM 1 1
Off Attenuation Mode
DESCRIPTION:
This command selects/reports the off attenuation mode of input channels 1-8.
RETURN VALUES:
Unit always returns the last executed off attenuation selection in the same form as above.
TEXT FORM DETAILS
COMMAND FORM: <DEVICE> OFFA <Channel> [Value]
Where:
<DEVICE>: See General Text command form Description
OFFA Text Command
Channel See Mic in Groups and Channels (Table 1, page 95)
Value
0-60 select off attenuation level (dB)
Null return the current off attenuation level
RETURN VALUES
The command will return the updated condition of the off attenuation level in the same format as the command.
If Command Returns
Off attenuation mode for channel 1 is set for 15dB DEVICE OFFA 1 15
Off attenuation mode for channel 1 is set for 0dB DEVICE OFFA 1 0