Specifications
TECHNICAL SUPPORT: 1.800.283.5936 (USA) OR 1.801.974.3760
APPENDIX E • SERIAL COMMANDS
136
Time Out Select
DESCRIPTION:
This command selects/reports the inactivity time out before returning to the unit title screen.
RETURN VALUES:
Unit always returns the last executed timeout selection in the same form as above.
TEXT FORM DETAILS
COMMAND FORM: <DEVICE> TOUT [Value]
Where:
DEVICE: See General Text command form Description
TOUT Text Command
Value
0 select disable unit time out
1-15 select time out of 1 to 15 minutes
Null return the current mode
RETURN VALUES
The command will return the updated condition of time out in the same format as the command.
If Command Returns
Time out is set to 3 minutes DEVICE TOUT 3
Unit ID
DESCRIPTION:
This command reports the unit ID. This command is read only.
RETURN VALUES:
Unit always returns the last executed unit ID selection in the same form as above.
TEXT FORM DETAILS
COMMAND FORM: <DEVICE> UID [Value]
Where:
DEVICE: See General Text command form Description
UID Text Command
Value UID of box in hex
RETURN VALUES
The command will return the unit ID in the same format as the command.
If Command Returns
UID DEVICE UID XXXXXXXX