Specifications

TECHNICAL SUPPORT: 1.800.283.5936 (USA) OR 1.801.974.3760
G-WARE SOFTWARE FILTER CONFIGURATION
51
Threshold determines the RMS level at which the compressor begins to operate.
The range is from -30 to +20dB. Default is 0dBu.
Ratio changes the rate of compression applied to the input signal as the signal
exceeds the threshold level. The range is 1:1 to 1:20dB. Default is 1:1.
Attack determines how quickly compression is enabled. It is calibrated in
milliseconds. The range is .5 to 100ms in .5ms steps. Default is 10ms.
Release determines how quickly compression is disabled. The range is 100ms to 2
seconds, in 5ms increments. Default is 500ms.
The Input peak meter shows the level of the signal as it enters the compressor. The
Compression peak meter shows the instantaneous compression value at a given
time.
When you are finished, click Close to return to the Processor Setup window.
Filter Configuration
The Filter button opens the Processing Filters window. Here, you can configure all
filters available in G-Ware: all pass, Bessel, Butterworth, CD horn, high pass, high
shelving, Linkwitz-Riley, low pass, low shelving, notch, and PEQ.
Processing Filters Window