Specifications

TECHNICAL SUPPORT: 1.800.283.5936 (USA) OR 1.801.974.3760
APPLICATION EXAMPLE MULTI-ROOM CONFERENCING
79
Room A
Room B
Room C
P1
P2
P3
Removable
Partition 1
Removable
Partition 2
Rooms B and C combined
P1
Removable
Partition 1
P4
Rooms A and B combined
P5
P3
Removable
Partition 2
Rooms A, B, and C combined
P6
S1
S2
S1
S1
S1
S2
S2
S2
Room A
Room B
Room C
Room B
Room B
Room A
Room A
Room C
Room C
1
2
34
Room-Combining Scenarios
Executing Presets Through the RS-232 Serial Port
You can configure presets such that one or more will remain on
continuously without interruption while other presets activate and
deactivate to accommodate changing room configurations. This is
accomplished by tailoring the Preset Execution/Reporting command (see
page 131).
Referring to the Room-Combining Scenarios diagram below, note that if you
want to switch from Configuration 1 (upper-left box) to Configuration 2, you
would most likely want P1 (preset 1) to remain on continuously without
resetting and rerunning again. This is because manual adjustments to
gating, muting, etc. might have been made in the P1 preset room during a
meeting in progress, and you don’t want to reset the preset to its original
settings at that moment.
The same rule would apply for P3 if you were switching between
Configurations 1 and 3—you would want P3 to remain on without
interruption.
To set up presets this way, set the argument commands based on the
following:
0 sets the preset state to Off.
1 executes the preset and sets the state to On.
2 executes the preset and sets the state to Off.