Specifications

TECHNICAL SUPPORT: 1.800.283.5936 (USA) OR 1.801.974.3760
APPENDIX B CONNECTOR PINOUTS
86
Table 2: Control/Status A Port Pinout (female)
Pin Number
User Definable* Status Momentary/Latching Default Description
1 Yes C M Lock front panel toggle
2 Yes S Status of front panel lock
3 Yes C M Mute all mics toggle
4 Yes S Status of mute all mics
5 Yes C M Mute Output 9 toggle
6 Yes S Status of Output 9 mute
7 Yes C M Mute Output 10 toggle
8 Yes S Status of Output 10 mute
9 Yes C M Mute Output 11 toggle
10 Yes S Status of Output 11 mute
11 Yes C M Mute Output 12 toggle
12 Yes S Status of Output 12 mute
13 Yes C M Volume Up D Output 1 (1dB)
14 Yes S Not programmed
15 Yes C M Volume Down D Output 1 (1dB)
16 Yes S Not programmed
17 No S Mic #1 Gate Status
18 No S Mic #2 Gate Status
19 No S Mic #3 Gate Status
20 No S Mic #4 Gate Status
21 No S Mic #5 Gate Status
22 No S Mic #6 Gate Status
23 No S Mic #7 Gate Status
24 No S Mic #8 Gate Status
25 No Ground Ground
13
25
1
14
Control/Status Ports A, B
Control/Status Connectors
The Control/Status connections are provided on two DB-25 connectors. These connectors are
labeled Control/Status A and Control/Status B and contain different types of pins. The inputs on
these connectors are internally pulled high and are activated by connecting the pin to ground. The
outputs are open collectors, which are open when inactive and grounded when active. This allows
the XAP 800 to control and be controlled by a wide variety of external devices, including relays,
lamps, switches, and other equipment.