3.1.3 Navigator Menu
Basic Application Builder
Basic Application Builder allows the user to graphically select and program a two-stage rundown
for Torque Control/Angle Monitor (Sequence 11/Sequence 30) or Angle Control/Torque Monitor
(Sequence11/Sequence 50) for any of the 8 Applications. The user only enters Torque, Angle,
and Speed Setpoints in one screen. Other parameters such as timers, etc are automatically
defaulted to pre-determined values.
Standard Application Builder
Standard Application Builder allows the user to program up to a 6-stage rundown for any of the 8
Applications. Once the fastening sequences are selected for each stage, the associated Torque,
Angle, Speed, and Advanced parameters can be programmed.
Advanced Application Builder
Advanced Application Builder allows the user to View and Edit all 8 Application setups at once,
and perform I/O Mapping. The Application Matrix shows an overview of Application and Stage
programming by displaying the selected Fastening Sequence for each stage. Stages can be
copied from one to the other or programmed directly from the Parameter soft key. I/O Mapping
lets the user select from a list of functions and assign that function to a given input or output.
RUN Screen
The Run Screen button takes the user directly to the display for Torque, Angle, and Status Indi-
cator Labels. The Oscilloscope function used for diagnosing torque traces is also located in the
Run Screen.
Communications
The Communications Setup allows the user to configure all communications for the Printer and
Serial Data Transmission. Appropriate communications settings for protocol, port, baud rate, etc
can be set in this screen.
Tool Setup
The Tool Setup displays the Tool Memory Data and allows the user to modify this information by
changing it directly or selecting from the Tool Library. The user can also create and save custom
tool setups under new model numbers.
Statistics
Chronological History and associated statistics are viewable from this screen. Data can be
erased and printed as well.
Diagnostics
The System Diagnostics contains screens to determine if the system is functioning properly.
There are diagnostics for I/O, Arcnet, Tool and Tightening Module, Serial Communications, and
Transducer Calibration.
Utilities
Utilities contains functions for upgrading or changing the system software. From the Utilities
screen the user can update the TME-100 application software from the floppy, install a new firm-
ware version in the Tightening Module from the floppy, or set the application software language
(English, German, Spanish, Portuguese).