Specifications

Cleco
Electric Tool Control TME-100 Series
22 PL12-1300 12/00 en03d141.fm, 30.01.2001
Fastening Strategies Torque Control/Angle Monitoring (Sequence 11/Sequence 30) or Angle
Control/Torque Monitoring (Sequence 11/Sequence 50) are selectable from the dropdown list-
box in the upper right hand corner of the screen. Once a Strategy is selected, the appropriate
Parameters will be displayed for programming.
3.2.1 Basic Parameters for Torque Control / Angle Monitor
Trigger Torque [Nm] - Torque to start collecting oscilloscope data.
Turnoff Torque Stage 1 [Nm] - Torque to change from stage 1 to stage 2.
Threshold Torque [Nm] - Torque to begin counting angle in stage 2.
Torque Low Limit [Nm] - Minimum acceptable torque.
Turnoff Torque Stage 2 [Nm] - Torque to turnoff the tool.
Torque High Limit [Nm] - Maximum acceptable torque.
Angle Low Limit [Deg] - Minimum acceptable angle.
Angle High Limit [Deg] - Maximum acceptable angle.
3.2.2 Basic Parameters for Angle Control / Torque Monitor
Turnoff Angle [Deg] - Angle to turnoff the tool.
The rest of the Parameters are the same as Torque Control/Angle Monitor except Turnoff
Torque Stage 2 is eliminated.
Below are the acceptable ranges for each Parameter and its default value. For initial program-
ming, the Parameters automatically use the default values.