Electric Tool Control TME-100 Series
en03d141.fm, 30.01.2001 PL12-1300 12/00 23
Cleco
3.2.3 Basic Application Builder Parameters
In the Basic Application Builder some parameters are not programmable and are also set to
default values. These values are located in the Standard Application Builder under Advanced
Parameters. However, if the parameters are changed using the Standard Application Builder,
then the Basic Application Builder does not reset them back to the default values.
3.2.4 Advanced Parameter Default Values
If an Application with more than two stages is required, or if a different Fastening Strategy has
previously been selected for the Application than described above, the Standard Application
Builder must be used.
Parameter Name Range Default
Fastening Strategy Torque Control/Angle Monitor
Angle Control/Torque Monitor
Torque Control/Angle Monitor
Trigger Torque [Nm] 0 to Tool Max 0.0
Turnoff Torque Stage 1 [Nm] 0 to Tool Max 0.0
Threshold Torque [Nm] 0 to Tool Max 0.0
Torque Low Limit [Nm] Threshold to Tool Max 0.0
Turnoff Torque Stage 2 [Nm] Low Limit to Tool Max 0.0
Torque High Limit [Nm] Turnoff to 1.2 TQ-Cal. value 0.0
Angle Low Limit [Deg] 0 to 9999 0.0
Turnoff Angle [Deg] Low Limit to 9999 0.0
Angle High Limit Turnoff to 9999 0.0
Speed Stage 1 [RPM] 0 to Tool Max 80% of Tool Max
Speed Stage 2 [RPM] 0 to Tool Max 50
Parameter Name Stage 1 Stage 2
Start delay time [mS] 0 0
Start spike time [mS] 0 0
Max. Fastening time [mS] 10000 10000
End delay time [mS] 0 30
Torque Filter Factor 1 1
If NOK go to stage Stop Stop
Print None All