Specifications

Cleco
Electric Tool Control TME-100 Series
24 PL12-1300 12/00 en03d141.fm, 30.01.2001
3.3 Standard Application Builder
3.3.1 Standard Application Builder / View Stages
Fig. 3-4: View Stages
From View Stages, Stages 1-6 and a Backoff Stage are programmable for a given tool and appli-
cation.
When the tool is started, each Stage having a programmed Fastening Sequence will be run in
succession based on the results from the previous stage. The Backoff Stage is used when the
tool is run in back-off direction or with the reverse button activated.
If a sequence has not been selected for a stage, then N/A is displayed for that stage. Otherwise
the Sequence number, description and icon are displayed. Sequences can be selected or
changed using the Select Seq (F1) soft key. This key is only valid when stages 1-6 are high-
lighted. The Fastening Sequence for the Backoff Stage is selected automatically.
The parameters for any stage can be programmed using the Parameters (F3) soft key. This key
is only valid when a Sequence has been selected for a given Stage.
c00280en.bmp