Specifications

Electric Tool Control TME-100 Series
en03d141.fm, 30.01.2001 PL12-1300 12/00 31
Cleco
The backoff parameters that are not displayed are set to values as in the table below.
For at tube nut tool the maximum speed for backoff ist 30% of Tool Max Speed. It is not possible
to enter a higher value.
3.3.4 Standard Application Builder / Advanced Parameters
Fig. 3-7: Advanced Parameters
The user can enter the Advanced Parameters using the Advanced (F3) soft key from the Param-
eter screen. These parameters are identical regardless of the selected Fastening Sequence.
The Next Stage (F2) key will increment to the next stage until it reaches the last stage with a
selected Sequence. It will then rollover to the first stage. In order to add a stage without a
selected Sequence the user must highlight the stage field and enter a number 1-6.
Parameter Name Sequence 41 Sequence 46
Start delay time [mS] 0 0
Start spike time [mS] 0 0
Max. Fastening time [mS] 10000 10000
End delay time [mS] 30 30
Torque Filter Factor 1 1
Torque Target --- 3,5% of Tool max. Torque
Torque High Limit --- 10% of Tool max. Torque
Angle Low Limit 0 0
Angle Target 9999 370
Angle High Limit 9999 380
c00283en.bmp