Specifications
Cleco
Electric Tool Control TME-100 Series
32 PL12-1300 12/00 en03d141.fm, 30.01.2001
Advanced Parameters
• Start delay time [mS] = time delay before the stage will start.
• Start spike time [mS] = time delay for the control system to start measuring torque after the
stage starts.
• Max. Fastening time [mS] = max time for the tool to run during the stage.
• End delay time [mS] = time delay from tool turnoff until shut-off of measured value recording.
• Torque Filter Factor = used for torque averaging.
• If NOK go to stage = gives the control system direction if the stage is NOK.
• Rundown Printout = gives the control system direction for when to print.
3.3.5 Advanced Application Builder / Application Matrix
Fig. 3-8: Application Matrix
The Application Matrix is a display matrix of 8 Applications vs. 6 Stages showing the selected
Sequence number for each stage. It gives the user an overview of controller programming in a
single screen.
Advanced Parameters Default Range of Values
Start delay time [mS] 0 0 - 999
Start spike time [mS] 0 0 - 999
Max. Fastening time [mS] 10000 1 - 60000
End delay time [mS] 30 0 - 999
Torque Filter Factor 1 1, 2, 4, 8, 16, 32
If NOK go to stage Stop Next; Error; Stop; 1; 2; 3; 4; 5; 6
Rundown Printout None OK; NOK; All; None
c00284en.bmp