Specifications
Cleco
Electric Tool Control TME-100 Series
34 PL12-1300 12/00 en03d141.fm, 30.01.2001
Eight optically isolated, +24V inputs are available at the Phoenix input connector under the right
side door and are defined as follows:
All inputs are active high. They are referenced to an isolated Input Common (pin 10). When
using the internal +24V (pin 1) to activate these inputs, you must connect Input Common (pin
10) and GND (pin 11).
3.3.7 Advanced Application Builder / Outputs
Fig. 3-11: Outputs
Inputs 0-2
Application Select 0-2: Application Selects 0-2 are used to select Applications 1-8
using a binary count of 0-7 where Applicaton Select 0 is the least significant bit.
This feature overrides application changes from the keypad.
Input 3
Tool Start (LCD and Outputs also clear): Starts the tool. Works in parallel with the
tool start switch.
Input 4
Activates the inputs I0 to I2 and I6.
Input 5
Tool Reverse: When active prior to tool start, the tool will run counter-clockwise
using the Backoff Strategy. Works in parallel with the tool reverse actuator.
Input 6
Tool Enable: When active allows the tool to start in conjunction with Tool Start.
Input 7
Synchronization Input: When active allows the tool to start from stage to stage in
conjunction with Tool Start.
c00286en.bmp