Fig. 3-12: Output Timing Diagram
Eight relay outputs are availiable at the Phoenix output connector under the right side door and
are defined as follows:
All relay outputs are active high. One side of all of the relay contacts is tied to a common supply
voltage point called Output Common (pin 2). When using the internal +24V (pin 1) as a source
for these outputs, you must connect Output Common (pin 2) and +24V (pin 1). The outputs will
then be referenced to GND (pin 11).
Output 0
Cycle OK: Active if Torque/Angle/Yield are within programmed limits.
Output 1
Cycle NOK: Active if Torque/Angle/Yield are outside limits or some other error has
occurred.
Output 2
Torque Low: Active if Peak Torque < Torque Low Limit
Output 3
Torque High: Active if Peak Torque > Torque High Limit
Output 4
Angle Low: Active if Final Angle < Angle Low Limit
Output 5
Angle High: Active if Final Angle > Angle High Limit
Output 6
Cycle Complete: Active whenever the fastening sequence is complete
Output 7
Synchronization Output: Active at the end of each stage to signal a stage is com-
plete.