Specifications

Cleco
Electric Tool Control TME-100 Series
40 PL12-1300 12/00 en03d141.fm, 30.01.2001
3.7 Tool Setup
Fig. 3-18: Tool Memory
The Tool memory data is displayed for the selected tool and redundancy. Only the Field Torque
Calibration (+/- 20% of nominal) is editable. If no Tool memory is available, then all data is pro-
grammable.
To change the tool memory the (F2) soft key must be pressed and a warning message will be
displayed. Then all fields are programmable except Serial number, Manufacture date, and Total
Cycles. When the tool memory is changed, the user name is also written to the tool memory for
traceability.
In case a tool with memory is changed to another tool with memory of the same type the tool will
continue to work without any necessary changes. In case the tool is changed to a tool without
memory or to a different type, then after power on or when pressing the start switch a message
is displayed which prompts the user to verify the Tool Setup.
62 62 1 Char ASCII Status Overall Status Flag
A = accept
R = reject
63 64 2 Digit ASCII Batch Count
(Only for Batch Count)
65 66 2 Digit ASCII Batch Size
(User programmable)
(Advances only on ACCEPT)
67 67 0D hex CR (carriage return)
68 68 0A hex LF (line feed)
Start End Length or Value Description