Specifications
Electric Tool Control TME-100 Series
en03d141.fm, 30.01.2001 PL12-1300 12/00 45
Cleco
3.10.2 Tool / Calibration
Fig. 3-24: Tool / Calibration
This test function cyclically recalibrates the system with the values used immediately before the
start of a rundown. The must be released for this function! The values "Calibration offset" and
"Calibration voltage" of the torque transducer are displayed. If redundancy is activated, the val-
ues of the second transducer are displayed. If a value is out of tolerance, it is shown in red.
Rated values and tolerances:
Value Rated value Tolerance
Calibration offset: 0 V +/-200 mV
Calibration voltage: 5 V +/-150 mV
c00299en.bmp