Specifications
Cleco
Electric Tool Control TME-100 Series
46 PL12-1300 12/00 en03d141.fm, 30.01.2001
3.10.3 Tool / Voltages
Fig. 3-25: Tool / Voltages
The table displays the measured voltages of a channel.
These are the most important supply voltages on the measuring board, required for proper
torque and angle measurement. Therefore, these must be monitored continuously. If a voltage is
out of tolerance, it is shown in red.
Designation voltage Rated value Tolerance
Logic voltage: +5 V +250 mV/-400 mV
Pos. analog Positive analog
voltage
+12 V ±600 mV
Neg. analog Negative analog
voltage
-12 V ±600 mV
c00300en.bmp