Specifications

Cleco
Electric Tool Control TME-100 Series
48 PL12-1300 12/00 en03d141.fm, 30.01.2001
3.10.5 Tool / TQ Measurement
Fig. 3-27: Tool / TQ Measurement
This test function recalibrates the system with the values used immediately before the start of a
rundown. The spindle must therefore be released still when this function is called up! Then the
tool is started at zero speed and the torque is continuously measured and displayed. The field
"Current torque" displays the current torque, "Peak torque" displays the highest value measured
since the start of the function. If "Redundancy" is activated, the values of the second transducer
are also displayed.
3.10.6 Tool / Speed
Fig. 3-28: Tool - Speed
When you press the tool start switch, the spindle starts with maximum speed. The current output
shaft speed is displayed. To achieve this, the angle factor must have been entered correctly,
c00302en.bmp
c00314en.bmp