Specifications

Cleco
Electric Tool Control TME-100 Series
68 PL12-1300 12/00 en05d141.fm, 30.01.2001
synchronization input when active allows the tool to start from stage to stage in
conjunction with tool start
synchronization output active at the end of each stage to signal a stage is com-
plete
threshold torque [Nm] torque to begin counting angle
tool enable when active allows the tool to start in conjunction with tool
start
tool rpm capability maximum allowable speed of the tool
tool reverse when active prior to tool start, the tool will run counter-
clockwise using the backoff strategy
tool start (LCD and Outputs
also clear)
starts the tool
tool stop stops the tool
torque capability indexes a measure of acceptable variation of final torque values in
a fastening process
torque control a fastening strategy by which you are controlling a tool by
predetermined torque limits
torque filter factor used for torque averaging
torque high active of peak torque > torque high limit
torque high limit (THL) the maximum acceptable torque value for one cycle
torque low active if peak torque < torque low limit
torque low limit (TLL) the minimum acceptable torque value for one cycle
torque monitoring a fastening strategy by which a tool is monitored based on
predetermined torque limits
torque reject a cycle rejected when the acceptable torque is not
achieved
torque threshold (TTH) the point at which the angle counting starts
transducer a device used to read torque
transducer span
(torque cal.)
full load reading of transducer
trigger torque [Nm] torque to start collecting oscilloscope data
turn off angle the angle at which a tool is shutoff
turn off torque the torque at which a tool is shutoff