Specifications
OPERATION
5680 330459 (10--08)
14
SOLUTION FLOW LEVER
The solution flow lever controls the amount of
solution flow to the floor.
Increase: Push the lever forward.
Decrease: Pull the lever backward.
NOTE: A solenoid valve dispenses the solution to
the scrub head. The valve opens when the
steering handles are rotated forward, and closes
when the steering handles are released in neutral
position.
NOTE: When using the FaST or ec--H2O system
(option), the solution flow lever is nonfunctional.
The FaST and ec--H2O system flow rates are
pre--set. The ec--H2O module has optional flow
rate settings. If solution flow adjustments are
required, contact an Authorized Service Center.
CIRCUIT BREAKERS
The circuit breakers are resettable electrical circuit
protection devices. They stop the flow of current in
the event of a circuit overload. Once a circuit
breaker is tripped, reset manually by pressing the
reset button after the breaker has cooled down.
If the overload that caused the circuit breaker to
trip is still there, the circuit breaker will continue to
stop current flow until the problem is corrected.
The circuit breakers are located on each side of
the operator console.
The chart shows the circuit breakers and the
electrical components they protect.
Circuit
Breaker
Rating Circuit Protected
CB1 10 A Machine power
CB2 25 A Vacuum fan motor
CB3 25 A Machine propel
CB4 30 A Right brush motor
CB5 30 A Left brush motor
CB6 10 A FaST (option)
10 A ec--H2O (option)