Stoves User Manual

23
Operating Instructions and Owner’s ManualCleveland Iron Works Wood Pellet Fire Stove
TROUBLESHOOTING CONTINUED
Too much fuel in the
firepot. The fuel can not be
completely and thoroughly
burned.
The feeding speed
is faster than what
combustion can
support.
1. Increase the fan’s speed to increase the rate of
combustion.
2. Reduce the feeding speed.
Not enough fuel in the
firepot.
The feeding speed
is too low to
support the rate of
combustion.
1. Decrease the fan’s speed to decrease the rate of
combustion.
2. Increase the feeding speed.
After the fire has started, the
stove turns off 15 minutes
later.
The pellet hopper is
low on fuel.
Check that the pellet hopper has a sufficient
amount of fuel.
The auger is not
operating.
1. Unplug the unit so that it will not start suddenly
and then unblock the auger.
2. Check that the auger is not blocked. If it is blocked,
remove the cause of the jamming.
3. Check that the auger screw fastening the auger to
the motor is secure.
The 30
o
C
temperature switch
has triggered.
1. Check that wires to the switch are sufficiently
connected.
2. Replace the 30
o
C temperature switch.
The pressure switch
inside the stove is
broken.
Replace the pressure switch.
Orange flame, pellets piling
up in firepot,carbon residue
forming on glass.
Insufficient air
for sufficient
combustion.
1. Check that the air inlet vent in the front is open.
2. Check that the door and window gaskets are
intact.
3. Check if the air inlet ducting and the combustion
exhaust ducting are blocked.
4. Increase the cross sectional area of the ducting.
5. Increase the fan’s speed to increase the rate of
combustion.
6. Contact the manufacturer for assistance.
SYMPTOM CAUSE SOLUTION