Manual

INSTRUCTION NUMBER: AO-70136 BA 3of 9
F G
J
E
H
D
W
LOAD CELL
PILLOW BLOCK
MOUNTING PLATE
A
BM N
K
C
L
1.4 DESCRIPTION
The Cleveland-Kidder Washdown Duty UPB
transducers utilize a sensing twin beam to which
semiconductor strain gages are bonded. With these
high output signal gages a very small force on the
sensing beam will be shown as a change in the tension
signal.
The type UPB transducers are for use with shafts that
are mounted in Pillow Block Bearings. See Figure 1.
For mounting dimensions see Figure 2.
Figure 1
Dimensions in Inches* Size
No.
A B C D E F(Max.) G H J (Max.) K L M N W
Maximum Working Force (lb.)
1 1.5 0.55 5.8 1.5 5/16 (4) 5.8 1.6 1.95 ½ (2) 1.40 6.5 1.3 2.2 2.2 25, 50, 100, 250, 500, 1000
2 3 0.80 10.0 3.0 ½ (4) 10.0 3.0 2.5 ¾ (4) 1.71 11.0 3.3 3.95 4.0 1000, 2500, 5000, 10000, 20000
3 4.5 1.63 15.0 4.5 1 (4) 15.6 5.0 4.2 1-1/8 (4) 2.80 17.0 4.8 5.2 6.5 10000, 20000, 30000
Dimensions in Millimeters*
Size
No.
A B C D E F(Max.) G H J (Max.) K L M N W
Maximum Working Force (N.)**
1 38 14 147.5 38 M8 147 40.5 49.5 M12 (2) 35.5 165 33 56 56 110, 225, 450, 1100, 2250, 4500
2 76 20 254 76 M12 254 76 63.5 M20 (4) 43.5 279.5 84 100 101.5 4500, 11000, 22000, 45000, 9000
3 114 41.5 381 114 M24 396 127 106.5 M30 (4) 71 432 122 132 165 45000, 9000, 13500
*Allow 2.5 inches (64 mm) clearance for connector
**Approximate rating in Newtons
Figure 2
Pillow Block Bearing
Washdown UPB Transducer