RECOMMENDED FLOOR
DRAIN DETAIL
ASSEMBLY
Position the kettle in it's permanent location, and
level the kettle by turning the adjustable flanged
feet. Once positioned and leveled, permanently
secure the kettle's flanged feet to the floor using
5/16" lag bolts and floor anchors (supplied by the
installer). There are three bolts required to secure
each of the flanged feet.
WIRE CONNECTION
Install in accordance with local codes and/or the
National Electric Code ANSI/NFPA No. 70-1990
(USA) or the Canadian Electric Code CSA
Standard C22.1 (Canada). A separate fused
disconnect switch must be supplied and installed.
The kettle must be electrically grounded by the
installer.
The electrical supply must match the power
requirements specified on the kettle's rating plate.
The copper wiring must be adequate to carry the
required current at the rated voltage.
Note: Maximum voltage for LVD (low voltage
directive for Europe) to be 440 volts for CE
marked appliances.
The kettle is wired for 3-phase operation at the
factory. For single phase operation, rewire the
terminal block to that shown in the above diagram.
Note: Ensure main power is turned off before
connecting wires.
Stationary Models
Remove the screws securing the dome-shaped
service cover underneath the kettle and remove
the cover. A wiring diagram is affixed to the inside
of cover. Fasten permanent copper wiring to the
three-connection terminal block, Be sure to
connect ground wire to the separate ground
terminal connector (ground lug). Slide the cover's
slot over the wiring and secure the cover to kettle
with the screws.
Tilting Models
First remove the handwheel by loosening the allen
screw. Then remove the two screws at the front
and rear of the console cover and remove the
cover. A wiring diagram is affixed to the underside
of the console cover. Feed permanent copper
wiring through the cut-out in the bottom of the
console, and fasten to the three-connection
terminal block. Be sure to connect the ground
terminal connector (ground lug). Replace the
console cover and handwheel.
WATER
The sealed jacket of the electric kettle is
precharged with the correct amount of a water-
based formula, and therefore, no water connection
is required to the kettle jacket. The kettle can be
equipped with optional hot and cold water taps,
the taps require 1/2" copper tubing as supply
lines.
RED
YELLOW
BLACK
BLACK
BLUE
RED
L1 L2 L3
THREE
PHASE
RED
YELLOW
BLACK
BLACK
BLUE
RED
L1 L2
SINGLE
PHASE
4" MINIMUM,
6" RECOMMENDED
PIPE DRAIN
RECOMMENDED
MINIMUM VALVE
SIZE PLUS 1"
FLOOR SLOPE
1" IN 4'
RECOMMENDED
FLOOR
DRAIN
(3) 7/16" DIA.
HOLES
FLANGED
FOOT (5" DIA)
3 1/8"
Flanged Foot Detail