- Cleveland Electric Floor Model Kettle Operators Manual

OPERATING INSTRUCTIONS
General Parts Drawing
ITEM # DESCRIPTION FUNCTION
1. On-Off Switch/Solid State Turns kettle ON/OFF and allows the operator to adjust the kettle
Temperature Control temperature in increments from 1 (Min.) to 10 (Max.).
(see Temperature Range Chart in the Operating Instructions
section).
2. Heat Indicator Light (Green) When lit, indicates that the kettle element is on.
Cycles ON-OFF with element.
3. Low Water Indicator Light (Red) When lit, indicates that the kettle is low on water and will not operate
in this condition. This will also light when the kettle is tilted.
4. Vacuum/Pressure Gauge Indicate steam pressure in PSI inside steam jacket as well as
vacuum in inches of mercury.
5. Pressure Relief Valve This valve is used to vent the kettle and in the unlikely event there is
(not shown) an excess steam build-up in the jacket, this valve opens
automatically to relieve this pressure.
6. Tilt Wheel Used for tilting the kettle up or down. Some units have an optional
Power Tilt Control Switch located in the same position.
7. Power Tilt Control Switch Used for tilting the kettle up or down.
(not shown)
8. Tangent Draw-Off Valve Used for draining product or wash water from kettle. It is supplied as
standard equipment on stationary kettles and is optional on tilting kettles
.
2
3
5
6
7
8
9
1
4
10
OFF
KE95555-2-A
CONTROL PANEL
CONTROL PANEL
3.
2.
1.
4.
5.
4.
5.
6.
8.
8.
TILTING KETTLE STATIONARY KETTLE