Operating instructions
6  INSTALLATION AND OPERATING INSTRUCTIONS
Note:
 When the ambient relative humidity is 1% lower than the 
selected relative humidity ratio percentage (RH %), the unit 
compressor will switch off and unit will operate at a Low (L) 
speed level.
Note:
 When the ambient relative humidity is 5% higher than the 
selected relative humidity ratio percentage (RH %), the unit will 
switch on and unit will operate at the selected SPEED setting.
Note:
 The unit will continuously run, regardless of the ambient 
relative humidity, when the CON (continuous dehumidification) 
mode is set.
5.  To select ON/OFF timer.
To set automatic OFF timer, press TIMER button when unit is 
powered ON; select the desired running time 1/2/4/8 hours 
respectively, timer LED lights will illuminate accordingly. Unit will 
automatically switch OFF once selected OFF time duration has 
lapsed. The screen will display time elapsed and remaining 
running time.
To set automatic ON timer, press TIMER button when unit is 
powered OFF or on standby mode, select the desired time for unit to 
start operating at 1/2/4/8 hours respectively, timer LED lights will 
illuminate accordingly. Timer symbol will be displayed on screen.
6.  To select auto dehumidification setting, press AUTO button, the 
AUTO LED light will remain illuminated. Unit will automatically 
adjustthehumiditysettingaccordingtotheambient
temperature.
Note:
 When the ambient relative humidity is less than or equal to 
24°C, the relative humidity ratio setting is 80%.When the ambient 
relative humidity is less than or equal to 24°C - 25 °C, the relative 
humidity ratio setting is 60%.When the ambient relative humidity 
is greater than or equal to 25°C, the relative humidity ratio setting 
is 40%.
Note:
 When AUTO humidity setting is activated, the previous 
relative humidity ratio or continuous mode will be deactivated.
7.  As unit operates, condensed water will drain into water 
reservoir. When water reservoir is full unit will beep 10 times 
and WATER FULL 
 indicator light will illuminate and all other 
indicator lights will turn orange. Unit will automatically stop 
operating. The water reservoir must be removed and emptied 
before unit will operate again. See Fig 1.
Note:
 Allow minimum of three minutes before turning unit on, after 
water reservoir is emptied.
Fig 1
Remove water 
reservoir in 
accordance with 
arrow direction