Datasheet

Normal
Stage 1
Trip
Stage 2
Reset
Stage 3
Bimetal
CIRCUIT BREAKER
AN Series
These compact overcurrent protectors are designed
to protect audio speaker systems, amplifiers and
power supplies from internal overcurrents. They are
available up to 12 amps.
FEATURES
High current accuracy. *
Protection against excessive temperature.
Snap action.
Automatic reset type.
Long life.
P.B.T. resin enclosure.
Economically priced.
Reliable.
Two mounting options.
* Low current models should be used within following
maximum ambient temperatures:
AN-04, AN-05 50°C
AN-06 60°C
AN-08 70°C
Note: Rated hold current decreases with temp
>25°C, and increases with temp <25°C.
AMBIENT TEMPERATURE AT 25°C
OVERLOAD CURRENT RATIO (%)
TRIP TIME (sec)
OPERATING
SEQUENCE
RATED HOLD MAX INTERNAL MAXIMUM
TYPE1 TYPE 2 CURRENT VOLTAGE 200% 300% RESISTANCE INTERRUPT
(A) (V) (m
) CURRENT
PC TAGS (A)
AN-041 - 0.4 250
within 30 secs within 5 secs
UNDER 700 4
AN-051 - 0.5 250 " " UNDER 600 5
AN-061 - 0.6 250 " " UNDER 500 6
AN-081 - 0.85 250 " " " 10
AN-101 AN-102 1.0 250 " " UNDER 150 20
AN-121 AN-122 1.25 250 " " " 20
AN-141 AN-142 1.4 250 " " UNDER 100 20
AN-161 AN-162 1.6 250 " " " 20
AN-171 AN-172 1.75 250 " " " 20
AN-191 AN-192 1.9 250 " " UNDER 75 20
AN-221 AN-222 2.2 250 " " " 20
AN-251 AN-252 2.5 250 " " " 25
AN-271 AN-272 2.7 250 " " " 25
AN-301 AN-302 3.0 250 " " UNDER 35 30
AN-401 AN-402 4.0 250 " " " 40
AN-501 AN-502 5.0 250 " " UNDER 30 50
AN-601 AN-602 6.0 250 " " " 60
AN-701 AN-702 7.0 250 " " " 60
AN-801 AN-802 8.0 250 " " " 60
AN-901 AN-902 9.0 250 " " " 60
AN-1001 AN-1002 10.0 250 " " " 60
AN-1201 AN-1202 12.0 250 " " " 60
TRIP TIME
OVERLOAD
AC at 25°C
CURRENT

Summary of content (1 pages)