Owner`s manual

Passenger Compartment Connections (Continued)
Brake Switch
The brake switch connection is required for the operation of the Concept 600’s anti-carjacking elec tronics.
1. Turn the ignition to the “ON” position and press the brake pedal to verify that the brake lights ar e operational.
2. Find the one wire that carries +12V when the brake pedal is pressed, then connect the BLUE/WHITE wi re to this wire.
Indicator Lights
See the Indicator Lights section in this binder.
Starter and Ignition AutoImmobilisation Circuits
1. Locate the ignition switch wireloom under the dash and use a voltmeter to locate the one wire that carries +12V throughout
BOTH the cranking AND engine running cycles, and 0 volts when the ignition is off.
2. Start the engine, then cut the ignition wire. The engine should stop running.
3. As shown on page 3, connect the BLACK wire with the Ignition Input +12 Volts label to the key side of the cut ignition line.
4.Connect the BLACK wire with the Ignition Output +12 Volts label to the engine side of the cut ignition line.
5.Use a voltmeter to locate the one wire that carries +12V during the cranking cycle ONLY. Cut this wire, then try to start the
engine. It should not crank.
6. Con nect the BLACK wire with the Starter In put +12 Volts la bel to the key side of the cut starter line.
7.Connect the BLACK wire with the Starter Output +12 Volts label to the engine side of the cut starter line.
NOTE: The starter cir cuit may carry a very high cur rent. Be cer tain that the starter wire con ne c tions are solid.
8. Remove the labels from each of the four wires.
Auxilliary A with Selectable Output Type
The auxilliary A output (GREY/VIOLET wire) can be programmed as either pulsed, latched or timed and can be programmed to
operate only when the system is disarmed (e.g., for use as a remote boot release). Auxilliary A ou tput is activated by transmitting
channel 2 from the master remote control or by pressing the button on the companion remote. The factory setting is pulsed
output (0.5 second ground). The latched output stays at ground until channel 2 is activated a secon d time, and the timed output
stays at ground for any selected duration between one second and four minutes. Current is limited t o 0.15 amp. See
Installer-Programmable Features on page 15 for information on programming the output type and/or disabling operation whilst the
system is disarmed.
Auxilliary B with Selectable Output Type
The auxilliary B output (GREY/BLUE wire) can be programmed as either pulsed, latched, or timed.
The auxilliary B output is activated
by transmitting channel 7 from the master remote or by pressing the
button on the companion remote. Current is limited to 0.15 amp.
The latched output stays at ground until channel 8 is activated a second time, and the timed output stays at ground for any selected
duration between one second and four minutes. See Installer-Programmable Featureson page 15 for more information on programming
output type.
Auxilliary C with Selectable Output Type and AutoActivation
The auxilliary C output (GREY/RED wire) can be programmed as either pulsed, latched or timed and in addition, can also be
programmed to automatically activate every time the system is armed using the remote control. The auxiliary C output is activated
by transmitting channel 8 from the master remote control or by pressing the and buttons on the companion remote. The
factory setting is pulsed output (0.5 second ground). AutoActivation is perfect when programmed as a timed-output to close the
power windows and sunroof on vehicles that have an all-close feature. The latched output stays at ground until channel 8 is
activated a second time, and the timed output stays at ground for any selected duration between one second and four minutes.
Current is limited to 0.15 amp. See Installer-Programmable Features on page 15 for information on programming the output type
and/or enabling the AutoActivation feature.
Window RollUp
Please refer to the Window Control section in this binder for information on the various circuit types and connections.
Con cept 600/299 7