Instructions / Assembly
 WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing 
property damage, personal injury, or loss of life.
Serial No: 
Model No: 
DANGER
CARBON MONOXIDE 
HAZARD
This appliance can 
produce carbon 
monoxide which has no 
odor. Using it in an 
enclosed space can kill 
you. Never use this
appliance in an enclosed
space such as a camper, 
tent, car or home. 
WARNING:
 WARNING:  Placing the cylinder too close to the appliance might cause the fire hazard or property loss or 
even life hazard.
Type of gas: propane
Normal hourly input: 50,000BTU/hr (14.65 kW)
Manifold pressure: 11 inch w.c. (2.74 kPa)
Maximum inlet supply pressure: 13 inch w.c. (3.24 kPa)
Minimum inlet supply pressure: 8 inch w.c. (1.99 kPa)
 CAUTION: The gas pressure regulator provided with this appliance must be used. 
This regulator is set for an outlet pressure of 11 inches water column. 
Minimum Clearance From Unit To Combustible Construction: 72” (182.9cm) from the top, 
24” (61cm) from all sides and back.
For Outdoor Use Only. If Stored Indoors, Detach and Leave Cylinder Outdoors.
The gas supply must be turned off at the LP-gas supply cylinder when this appliance is not in use.
Complies with ANS Z21.97-2017 CSA 2.41-2017, Outdoor Decorative Gas Appliance Standards.
Cover must be removed when burner is in operation.
Removal of this marking will void compliance with standard ANS Z21.97-2017 CSA 2.41-2017.
Do not connect to a remote gas supply. 
The instruction manual contains important information necessary for the proper assembly and safe use of the appliance.
Read and follow all warnings and instructions before assembling and using the appliance.
Follow all warnings and instructions when using the appliance.
Do not store or use gasoline, or other flammable vapors and liquids, in the vicinity of this or any other appliance. 
An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
 WARNING: Improper 
installation, adjustment, 
alteration, service or 
maintenance can cause 
property damage, personal 
injury or loss life. Refer to 
the owner's information 
manual provided with this 
appliance. Installation and 
service must be performed 
by a qulified installer, 
service agency, or the gas 
supplier.
If instructions or parts are missing, please email us at operator@ehomexpert.com
Xiamen Ecotop Industrial Co., Ltd.
Shangtang North Road, 
Xiang'an District, 
Xiamen 361100, P.R.C.
 CAUTION: This appliance has been converted to use natural gas. Propane orifice dia 2.21 mm, 
natural gas orifice dia 4.18 mm. 
Rated Heat Input: 50,000BTU/hr (14.65 kW). 
Type Gas: Natural gas
Manifold Pressure: 7 inches water column (1.74 kPa).
This appliance was converted on (day-month-year) to 
(insert gas type; e.g. Natural or Propane) gas with Kit. No. by 
(name and address of organization making this conversion), which accepts the responsibility that this 
conversion has been properly made.
Figure 15 Figure 16
Figure 17
4. Connect the natural gas hose to the gas valve by screwing clockwise tightly (see Figure 15). Plug the natural gas 
 fixture into the natural gas supply system (see Figure 16). The conversion kit should be CSA certified. Below are 
 several suggested CSA certified conversion kits for your reference. 
 (1). Part# DH22 / QH1, manufacturer: KSUN 
 or (2). Part# WH02 / KJ50A2, manufacturer: Laite 
 or (3). Part# KJ-3/8G-3/8 / KJ-3/8G, manufacturer: Wanan
 The natural gas orifice is included in the package. Please follow the instructions for gas conversion.
5. Stick and cover the conversion label onto the propane rating plate (see Figure 17).
gas valve
natural gas hose
natural gas fixture
natural gas supply system
conversion label
propane rating plate
WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the 
manufacturer’s intructions and all applicable codes and requirements of the Authority Having Jurisdiction. 
If the information in these instructions is not followed exactly, a fire, explosion or production of carbon 
monoxide may result causing property damage, personal injury or loss of life. The qualified service agency 
is responsible for the proper installation of this kit. The installation is not proper and complete until the 
operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied 
with the kit.
11