MT-01 Indice 0 Page 22
Check the functionality of the thermostat: if it is faulty, replace it (only to be completed by specialist
technicians)
Is the compressor cooling?
Several minutes after the compressor has been operating, place your hand on the evaporator inside
the cabinet:
If it is cold the refrigeration process is in progress.
If it is not cold, refer to the checks listed below.
Is the compressor continuously in operation?
Yes:
Check that there is no gas leak or an obstruction on the refrigerating circuit.
Replace the faulty part (condenser, evaporator, repair the welding) (only to be completed by
specialist technicians).
No:
Check the thermostat setting and adjust if necessary.
Check the gas load in the system, if there is not enough; refill it if necessary (only to be completed by
specialist technicians).
3.6 The temperature is too low when a reading is taken with a submerged thermometer
Is the device situated in an unheated environment?
Check this during the winter and ensure that the wine cabinet model is equipped with a winter
system.
How many readings were taken? How? Using what type of device?
Ensure that the value indicated is not the result of an instant reading taken while the compressor
was shut down (the internal temperatures then rise again).
Where is the thermostat located?
Adjust the position of the thermostat if necessary.
What is the local ambient temperature?
If the area is cold and the cabinet is equipped with a winter system, check the:
- Heating thermostat
- Element
And replace if necessary.