Owner’s Manual Using the Ducted Evaporative Air Conditioning with Your Manual Control Operating, Installation & Maintenance Please keep this important manual in a safe place. It is the owner’s responsibility to ensure that regular maintenance is carried out on this Ducted Evaporative Air Conditioner. Failure to do so will void all guarantees beyond statutory and legal requirements. www.climatetechnologies.com.
Manual Comfort Control Notes Introduction Congratulations on your choice We are delighted you have chosen an air conditioning product from Climate Technologies to cool your home. It’s an air conditioner we’re very proud of. Designed and made in Australia by Climate Technologies, a 100% Australian owned company, it contains the latest advances in Fresh Air Conditioning technology in a stylish, attractive cabinet.
Manual Comfort Control Notes INTRODUCTION ................................................................................................2 CONGRATULATIONS ON YOUR CHOICE ......................................................................... 2 DUCTED EVAPORATIVE AIR CONDITIONING ...............................................5 INTRODUCTION .......................................................................................................... 6 UNIT OPERATION .........................................
Manual Comfort Control Notes PNE2002 Series Control Page 4
Manual Comfort Control Ducted Evaporative Air Conditioning Ducted Evaporative Air Conditioning Owners Operating and Maintenance PNE2002 Series Control Page 5
Manual Comfort Control Ducted Evaporative Air Conditioning Introduction Your ducted evaporative air conditioner is engineered to meet the rigors of our harsh Australian environment. Operated and maintained in accordance with this manual, it will provide you with years of quiet, cool and environmentally friendly operation. Please take the time to read this manual. The principal of your unit is to introduce fresh air, which is washed through the filter pads to provided cool fresh air.
Manual Comfort Control Ducted Evaporative Air Conditioning Bleed-off All evaporative air conditioners need some water bleed-off to prevent build-up of mineral deposits in the system. The correct setting of the bleed rate will ultimately govern the life of the unit. With normal town water supply, bleed rate should be adjusted so that the discharge is not less than approximately 10 litres per hour. Increased water hardness may require a higher bleed rate and increased maintenance.
Manual Comfort Control Operating the Controls Operating the Controls Control Functions The MANUAL control is a simple low voltage controller that allows you to operate each function of the product as required to keep you home cool. As there is no thermostat in the Manual control it can be located anywhere that is convenient to the customer and the installer. To use the control you will need to turn the fan ON, or the fan and cool switches ON to operate .
Manual Comfort Control Control Installation & Setup Control Installation & Setup Installing The Control Before Starting Before attempting to locate the control, check that the 20 metre cable supplied will reach between the air conditioner and the proposed wall control position. For the unit to function a jumper supplied with the wall control must be fitted to the air conditioner control box. NOTE: Do not run the low voltage loom in long parallel runs with 240V mains cables.
Manual Comfort Control Control Installation & Setup Setting Up The Control The MANUAL control does not come with any maintenance functions to set the high or low fan speeds. To set the high or low fan speeds an RF/LV digital control is required to set and save the settings in the unit control. Setting Minimum Fan Speed 1. Using the MANUAL/AUTO button set the unit to MANUAL 2. Using the HEAT/COOL/FRESH AIR button set the unit to COOL FRESH AIR 3.
Manual Comfort Control Control Installation & Setup Problem Solving PROBLEM Unit fails to start Pump fails to start Water leaking from overflow Water Droplets in air stream Excessive humidity Inadequate Cooling Unpleasant Odor Rapid formation of white deposits on pads PROBABLE CAUSE REMEDY a Black – out a Wait b Tripped Circuit Breaker b Reset c Blown Fuse c Replace d Electrical Fault d Call Climate Technologies Service Provider a Pump Seized a Isolate power and then take off top of pum
Manual Comfort Control Control Installation & Setup Commissioning Check List General All equipment ordered by the customer is installed. The unit is level and secure. The mains and control wiring are complete and the circuit breaker and GPO are turned ON. All Controller functions for the appliance operate. All electrical or water connections are to manufacturers specifications and the relevant electrical or plumbing standards and codes.
Manual Comfort Control Control Installation & Setup Ductwork All ductwork is completed to plan, correctly supported and airtight, with no bend less than 1.5 x the ductwork diameter. Air distribution checked, dampers are adjusted and all outlets correctly adjusted and wiped clean. All roof penetrations are fully sealed and watertight. Man hole cover replaced. Site All rubbish has been removed from inside and on the roof. Customer Hand Over The operation of the Controller.
Manual Comfort Control Unit Mantenance DUCTED EVAPORATIVE AIR CONDITIONER MAINTENANCE General All Ducted Evaporative Air Conditioners benefit from some general maintenance to ensure continued cooling efficiency and a long life. Maintenance is carried out at the beginning and end of summer to start up and close down your unit. We recommend that all maintenance work be undertaken by our fully trained and accredited Service Technicians or an authorized Climate Technologies Service Provider.
Manual Comfort Control Unit Mantenance Water Level / Float Valve The water level should be set at nominal 65-70mm from the top of the overflow before filter pads are saturated. After run off from the operating pump / filters the level from the top of the overflow fitting should be 25 – 30mm. The float valve is a mechanical type and is factory set. If it requires adjustment keep bends tight. If the valve is leaking the seal may require cleaning or replacing.
Manual Comfort Control Warranty – Australia ONLY Warranty Warranty Statement. Subject to the following conditions we provide, from the dated proof of purchase, the following warranty: Any part found to be defective in workmanship or material within the period of warranty will be replaced free of charge. The structural warranty covers any structural components within the unit, which fail to perform their intended function due to faulty manufacture or deterioration within the warranty period.
Manual Comfort Control Warranty – Australia ONLY Warranty On Replacements Parts. Parts replace under warranty are warranted for the balance of the original warranty period. Period Of Warranty – Years Unit Components RESIDENTIAL Parts Labour COMMERCIAL Parts Labour Corrosion on Cabinet 25 3 2 2 Structural Guarantee 10 3 2 2 ** All other components 3 3 1 1 ** Filter pads are a consumable item and therefore are not covered by the above warranty periods.
Manual Comfort Control Warranty – Australia ONLY Proof Of Purchase It is important that the name of the Dealer or Retailer from whom you purchased your product and the name of the installer is recorded on this page. The installer is responsible for the correct installation, start up and demonstrating the operation of this product. He is also responsible for issuing the relevant certificates of compliance for the electrical and gas connections.
Manual Comfort Control Warranty – Australia ONLY SERVICE. A qualified service technician should conduct any service work carried out on your ducted gas central heating or cooling product. It is important that periodical service is carried out on your product to ensure your will receive the efficiency benefits the product provides. An authorized Climate Technologies service provider must carry out warranty service. For Metro Service only ring the numbers below.