ATC32U01 iGate™ Communicating, Programmable Thermostat User Manual 97B0055N02 Created: 5/8/12 Table of Contents Section Title Page 1.0 2.0 3.0 4.0 5.0 Temperature Adjustment Operating Mode Selection Fan Mode Selection Humidity Level Adjustment Main Menu Options Overview Date and Time Hold Program 3 3 4 4 5 6 6 8 5.1 5.2 5.3 Section 5.4 5.5 5.6 5.7 5.8 6.0 7.
This page was intentionally left blank.
AT C 3 2 U 0 1 C o m m u n i c a t i n g , P r o g r a m m a b l e T h e r m o s t a t - U s e r M a n u a l C r e a t e d : 8 M a y, 2 0 1 2 ClimateMaster’s ATC32U** Communicating, Programmable Thermostat is the perfect compliment to your ClimateMaster Geothermal Heat Pump System and represents a significant advancement in thermostat communicating technology.
AT C 3 2 U 0 1 C o m m u n i c a t i n g , P r o g r a m m a b l e T h e r m o s t a t - U s e r M a n u a l C r e a t e d : 8 M a y, 2 0 1 2 3.0 Fan Mode Selection 10/13/11 To adjust the Fan Mode on your thermostat, use the left/ right arrow buttons to select the FAN user option from the Home Screen and then press the center button. The Fan Menu shows up to 3 possible Fan Operating Modes with the currently active Fan Operating Mode highlighted.
AT C 3 2 U 0 1 C o m m u n i c a t i n g , P r o g r a m m a b l e T h e r m o s t a t - U s e r M a n u a l C r e a t e d : 8 M a y, 2 0 1 2 5.0 Main Menu Options Overview MENU 5.1 DATE AND TIME 5.1.1 AUTO DAYLIGHT SAVING 5.1.2 SET DATE AND TIME 5.1.3 DISPLAY DATE AND TIME 5.2 5.3 5.4 5.5 5.6 HOLD PROGRAM FAN MODE SETTINGS 5.6.1 SCREEN SETTINGS 5.6.1.1 Fahrenheit or Celsius 5.6.1.2 12 or 24 Hour Clock 5.6.1.3 Language 5.6.1.4 Contrast 5.6.1.5 Backlight On Time 5.6.1.6 Date Display 5.6.2 OFFSETS 5.6.2.
AT C 3 2 U 0 1 C o m m u n i c a t i n g , P r o g r a m m a b l e T h e r m o s t a t - U s e r M a n u a l C r e a t e d : 8 M a y, 2 0 1 2 5.0 Main Menu 10/13/11 8:27 AM Access main menu by selecting MENU on the main screen. 5.1 DATE AND TIME The thermostat can be programmed for daylight savings, date and time, and to display date and time on the main screen. 5.1.1 AUTO DAYLIGHT SAVING When enabled, the thermostat automatically adjusts the time for daylight savings time. 5.1.
AT C 3 2 U 0 1 C o m m u n i c a t i n g , P r o g r a m m a b l e T h e r m o s t a t - U s e r M a n u a l C r e a t e d : 8 M a y, 2 0 1 2 • Heat Setpoint (default current Heat Setpoint): valid range: 55°F to Maximum Heating Setpoint Limit (section 5.6.8) • Cool Setpoint (default current Cool Setpoint): valid range: Minimum Cooling Setpoint Limit (section 5.6.8) to 95°F NOTE: The thermostat forces a 2°F “dead-band” between the Heating and Cooling setpoints.
AT C 3 2 U 0 1 C o m m u n i c a t i n g , P r o g r a m m a b l e T h e r m o s t a t - U s e r M a n u a l C r e a t e d : 8 M a y, 2 0 1 2 5.3 PROGRAM The Program Display Mode includes options to copy schedules as well as create/edit schedules for individual days or schedules for groups of days. 5.3.1 CREATE / EDIT SCHEDULE This function allows you to set the time, heat setting, cool setting, and fan operation for each program schedule event of the day.
AT C 3 2 U 0 1 C o m m u n i c a t i n g , P r o g r a m m a b l e T h e r m o s t a t - U s e r M a n u a l C r e a t e d : 8 M a y, 2 0 1 2 5.6 OTHER SETTINGS 5.6.1 SCREEN SETTINGS Adjust the Screen settings using the up/down arrow buttons. Press the center button to save changes.
AT C 3 2 U 0 1 C o m m u n i c a t i n g , P r o g r a m m a b l e T h e r m o s t a t - U s e r M a n u a l C r e a t e d : 8 M a y, 2 0 1 2 by the Programmed Demand Reduction option selected below. NOTE: The thermostat must be configured for programmable mode by installer to access the Programmed Demand Reduction settings. 5.6.5.5.1 PROGRAMMED DEMAND REDUCTION MODE Through Programmed Demand Reduction Mode, you can set the unit’s limited operation during the Programmed Demand Reduction schedule.
AT C 3 2 U 0 1 C o m m u n i c a t i n g , P r o g r a m m a b l e T h e r m o s t a t - U s e r M a n u a l C r e a t e d : 8 M a y, 2 0 1 2 • Off Time: options: 5 to 90 minutes (in 5 minute increments) NOTE: This intermittent fan operation can also improve the performance of air cleaning or special filtration systems that locate the cleaning or filtration media at the return air side of the fan. 5.6.
AT C 3 2 U 0 1 C o m m u n i c a t i n g , P r o g r a m m a b l e T h e r m o s t a t - U s e r M a n u a l C r e a t e d : 8 M a y, 2 0 1 2 Adjust the Demand Reduction Climadry™ settings using the up/down arrow buttons. Press the center button to save changes. • Suspend Climadry™ (default): While the assigned Demand Reduction input is active, Climadry™ is turned off, regardless of the dehumidificaiton demand.
AT C 3 2 U 0 1 C o m m u n i c a t i n g , P r o g r a m m a b l e T h e r m o s t a t - U s e r M a n u a l C r e a t e d : 8 M a y, 2 0 1 2 • Night Setback Override (default 2 hours): options: 1 to 8 hours (in 15 minute increments) activated, regardless of the dehumidification demand. 5.8.3 NIGHT SETBACK DEMAND REDUCTION Through Night Setback Demand Reduction Mode, you can set the unit’s limited operation while Night Setback is active. 5.8.5.
AT C 3 2 U 0 1 C o m m u n i c a t i n g , P r o g r a m m a b l e T h e r m o s t a t - U s e r M a n u a l C r e a t e d : 8 M a y, 2 0 1 2 7.0 Revision History Page # 8 May, 12 All Description First Published R AI BR I HE AT P U M P S A TO NE WATER TO IFIED TO ARI A RT S C CE NG WITH LYI MP O IR MANUFACT UR ER Date IS ST AND 3 ARD 1 -1 R O 25 6 ISO 9001:2000 Certified Quality: First & Always 7300 S.W.