GT-PCS Split Units - 60Hz Puron
®
Created: 29 Aug., 2013
Hot Water Generator Module Refrigeration Installation
Outdoor Compressor Section Only
Fully Insulated
Lines to the HWG
Refr to
HWG
Refr from
HWG
Figure 21d: HWG Service Valves
Figure 21c: HWG Bypass Valve
Valve Open
(HWG Bypassed)
Valve Closed
(HWG Activated)
Figure 21b: Remote HWG Module
Capacity
Line Set Size
1/2” OD 5/8” OD 3/4” OD
2 Ton
Up to 16 ft.
[4.9m]
Up to 30 ft.
[9.1m]
N/A
3 Ton
Up to 9 ft.
[2.7m]
Up to 25 ft.
[7.6m]
Up to 30 ft.
[9.1m]
4 Ton
Up to 5 ft.
[1.5m]
Up to 13 ft.
[4.0m]
Up to 30 ft.
[9.1m]
5 Ton N/A
Up to 9 ft.
[2.7m]
Up to 25 ft.
[7.6m]
HWG
Line Valves
HWG
Bypass
Valve
Refr
to HWG
Refr from
HWG
Pump
Relay
Circulator
HWG
Water Out
HWG
Refr Out
HWG
Refr In
High Voltage
HWG
Water In
Table 10: HWG Refrigerant Line Sizing
Figure 21a: Outdoor Compressor Section HWG Installation