Instruction manual

21INSTRUCTION MANUAL
>> HUMIDIFY SETPOINT: Allows you to increase and maintain the relative humidity
at a specific setpoint. Once you choose HUMIDIFY follow these easy steps:
:: The HUM setpoint with - and + icons allow you to lower and raise your setpoint.
* Example of the typical use of the Humidify Function: If the current humidity is 30% your
Climatouch
thermostat will initiate the humidifier to function until Setpoint 50% is
reached. In order to humidify you must set the humidity setpoint above the current
humidity.
HUMIDIFY AND HUMIDITY SETPOINT
20 Climatouch
CT0-7TC-32H
DE-HUMIDIFY AND HUMIDITY SETPOINT
>> DE-HUMIDIFY SETPOINT: Allows you to reduce and maintain the relative humidity
at a specific setpoint.
>> Please note that this feature functions in the COOL Mode only. Your Climatouch
Thermostat must be configured to control a cooling unit such as an air conditioner
of heat pump. Once you choose De-Humidify follow these easy steps:
:: The DH SETPOINT with - and + icons allow you to lower and raise your setpoint
* Example of typical use of the De-Humidify function: In order to de-humidify you must
set the de-humidify setpoint below the current relative humidity. Your Climatouch
will
both lower and regulate temperature to the cooling setpoint while monitoring and
lowering the room humidity.
Since the De-Humidify feature uses the COOL Function of your Air Conditioner or
Heat Pump, your Climatouch
thermostat will turn off the air conditioning if either the
dehumidifier setpoint or temperature setpoint is reached - which ever comes first.