Instruction manual

ADVANCED SETTINGS - CALIBRATION
43INSTRUCTION MANUAL
>> Temperature Calibration Table
:: Determine the temperature difference using an accurate thermometer, then use
the following table to adjust your thermostat calibration.
THERMOSTAT FAHRENHEIT CELSIUS
CALIBRATION NUMBER CHANGE CHANGE
+3.0 +6°F +3.0°C
+2.5 +5°F +2.5°C
+2.0 +4°F +2.0°C
+1.5 +3°F +1.5°C
+1.0 +2°F +1.0°C
+0.5 +1°F + .5°C
FACTORY RELATIVE NO CORRECTION
SETTING HUMIDITY CHANGE REQUIRED
-0.5 -1°F -.5°C
-1.0 -2°F -1°C
-1.5 -3°F -1.5°C
-2.0 -4 °F -2.0°C
-2.5 -5°F -2.5°C
-3.0 -6°F -3.0°C
ADVANCED SETTINGS - CALIBRATION
42 Climatouch
CT0-7TC-32H
>> Calibration of Temperature or Relative Humidity
Your Climatouch
Thermostat is rated for an accuracy of +/-1 degree with
temperature and +/- 4% for Relative Humidity
If you have determined due to drafts, sunlight or other environmental factors that your
thermostat requires calibration, follow this easy guide. Common cause of offset are lack
of air circulation, drafts or skylights in the direct vicinity of your Climatouch unit.
Measure humidity with a conventional hygrometer or any other device that provides
a accurate reading. Then compare to the reading on your Climatouch
and calibrate
by up to +/- 15 degrees.