ADVANCED SETTINGS - HUMIDITY SETTINGS
39INSTRUCTION MANUAL
>> IMPORTANT: The Automatic Humidity Control feature can only be activated
when used with the Climatouch
™
Outdoor Wireless Temperature Transmitter
and Receiver. Please install the Climatouch
™
Outdoor Wireless Temperature
Transmitter and Receiver before activating this feature.
Automatic Humidity Control: Automatic humidity control is an option that lets your
system automatically adjust indoor humidity based on current outdoor conditions.
This function minimizes destructive condensation build-up on your windows.
:: HUM FAN: ON - fan runs when there is an independent demand to humidify.
OFF: fan only runs when there is a demand to humidify while heating or cooling.
:: DH FAN: ON - fan runs when there is an independent demand to dehumidify.
OFF: fan only runs when there is a demand to dehumidify while cooling.
:: DH REVERSE: ON - DH relay is normally closed when relative humidity is above
DH set point. OFF: DH relay is normally open when relative humidity is above DH
set point.
:: DH CONTROL COMPRESSOR: ON - Thermostat will turn off the air conditioning
if either the dehumidify set point or the temperature set point is reached, whichev-
er comes first, both DH relay and compressor will turn off. OFF: DH relay is inde-
pendent of compressor activity (DH becomes a spare relay and can be used for a
variable speed fan or separate dehumidifier or air exchanger)
ADVANCED SETTINGS - HEAT PUMP
38 Climatouch
™
CT0-7TC-32ADH
:: HP ON when Furnace On: Heat Pump and Furnace can operate together when
2nd stage furnace is required. HP “OFF” when Furnace On: turns off the Heat
Pump when the furnace is On (required on some gas or oil furnaces).