ADVANCED SETTINGS - HUMIDITY SETTINGS
39INSTRUCTION MANUAL
>> IMPORTANT: The Automatic Humidity Control feature can only be activated
when used with the Climatouch
Outdoor Wireless Temperature Transmitter
and Receiver. Please install the Climatouch
Outdoor Wireless Temperature
Transmitter and Receiver before activating this feature.
Automatic Humidity Control: Automatic humidity control is an option that lets your
system automatically adjust indoor humidity based on current outdoor conditions.
This function minimizes destructive condensation build-up on your windows.
:: HUM FAN: ON - fan runs when there is an independent demand to humidify.
OFF: fan only runs when there is a demand to humidify while heating or cooling.
:: DH FAN: ON - fan runs when there is an independent demand to dehumidify.
OFF: fan only runs when there is a demand to dehumidify while cooling.
:: DH REVERSE: ON - DH relay is normally closed when relative humidity is above
DH set point. OFF: DH relay is normally open when relative humidity is above DH
set point.
:: DH CONTROL COMPRESSOR: ON - Thermostat will turn off the air conditioning
if either the dehumidify set point or the temperature set point is reached, whichev-
er comes first, both DH relay and compressor will turn off. OFF: DH relay is inde-
pendent of compressor activity (DH becomes a spare relay and can be used for a
variable speed fan or separate dehumidifier or air exchanger)
ADVANCED SETTINGS - HEAT PUMP
38 Climatouch
CT0-7TC-32ADH
:: HP ON when Furnace On: Heat Pump and Furnace can operate together when
2nd stage furnace is required. HP “OFF” when Furnace On: turns off the Heat
Pump when the furnace is On (required on some gas or oil furnaces).