System information

C0240111-06-07-GB
38
Mask Description Para n°
Slave calibr. exp2
offset Value
B5: 0.0°C 22.3°C
B6: 0.0°C 24.2°C
Modifies the probe offsets of expansion 2. (Only present if required by the type of machine
configured)
31.25
31.26
Slave calibr. exp2
offset Value
B7: 0.0°C 22.4°C
B8: - -
Modifies the probe offsets of expansion 2. (Only present if required by the type of machine
configured)
31.27
31.28
Slave calibr. exp3
offset Value
B1: 0.0°C 05.3°C
B2: 0.0°C 00.0°C
Modifies the probe offsets of expansion 3. (Only present if required by the type of machine
configured)
31.31
31.32
Slave calibr. exp3
offset Value
B3: 0.0°C 00.0°C
B4: 0.0°C 00.0°C
Modifies the probe offsets of expansion 3. (Only present if required by the type of machine
configured)
31.33
31.34
Slave calibr. exp5
offset Value
B1: 0.0°C 00.0°C
B2: 0.0°C 00.0°C
Modifies the probe offsets of expansion 5. (Only present if required by the type of machine
configured)
31.51
31.52
Slave calibr. exp5
offset Value
B3: 0.0°C 00.0°C
B4: 0.0°C 00.0°C
Modifies the probe offsets of expansion 5. (Only present if required by the type of machine
configured)
31.53
31.54
User
Password: 0000
Access mask to user menu. Enter the user password for access.
User
Access mask to user menu.
Press "Up" or "Down" to scroll the other masks and "Esc" to
return to the submenu.
Step adjustment
type
IN INLET
Chooses between proportional step adjustment, Quick Mind adjustment and modulating
adjustment for screw compressors. Also defines on which temperature probe the adjustment
is made. If the unit has more than one evaporator or step adjustment is set, adjustment can
only be made on the inlet probe.
39.01
39.01
39.02
Time bands
enable:
Disabled
Activates/deactivates time bands.
The time bands cannot be activated if the external setpoint
is enabled.
39.41
Serial line
configuration:
Disabled
Allows the devices connected to the serial interface board to be enabled and selected (
"0"=disabled, "1"= supervision, "2"= sequencer, "3"=Manager 3000). N.B.: the Service
software does not need to be enabled.
39.42
En. from superv.:
On/Off: N
Operating mode: N
Allows the on/off status of the unit to be selected from a supervision system.
Also performs
operating mode switching (to modify the latter, the unit must be switched off).
39.43
39.44
Superv. setting
Modbus protocol
Speed 9600 baud
ID 011
Defines the connection parameters with the supervisor: protocol type, communication speed
and unit identification number.
39.45
39.46
39.47
Select language:
English
Select language
Selects the required language; “Select language” flashes on the last line in all the available
languages. Once a language has been selected, the programme automatically switches to
the first mask of the display menu.
N.B.: Up to three languages are present on the board: Italian, English and another language.
39.48
W 3000
Code CA 15.00 GB 
Man. C0240001-06-07
This mask contains the reference information of the software [Code] and of the reference
technical manual [Man.].
The closed padlock symbol shows that the board is provided with its propriety software; two
padlocks appear on units with 3 or 4 circuits
Enter another
user
password
0000
Personalises the password by defining one that will replace the default password.
Unit
Access mask to unit menu.
Press "Up" or "Down" to scroll the other masks and "Esc" to
return to the submenu.
Temp. In. Out.
Evap. 12.5 07.0°C
Rec. 35.6 40.5°C
Cond. 38.0 42.5°C
Displays inlet and outlet temperatures of the evaporator, recuperator and condenser (where
fitted).
Temp. In. Out.
Evap. 12.5 07.0°C
Evap1 07.2°C
Evap2 06.9°C
(if 2 evaporators are fitted) Displays inlet and outlet temperatures of the evaporator or
condenser (depending on whether the unit is in the chiller or heat pump mode) and the outlet
temperature of the two evaporators.