User's Manual

16
If an alarm is triggered by WTRVS or
CTC-808RV, Monitoring Center
personnel will have to press DTMF 2 for
over 1 second to open two-way
communication regardless of the
Follow-On choice you have set.
Command 46
Follow-On Mode & Two-Way Period
This command is used to program the
allowable time duration for Follow-On
mode choice (Commend #45) & Two-way
voice communication period (Speech
mode). It can be set from (01) (1 minute) -
(10) (10 minutes).
Function Selection
Result
(01) 1 MINUTE
(02) 2 MINUTES
(03)-(10) 3-10 MINUTES
Factory default is set as (02) 2 minutes.
The allowable time duration for either Wait
Command, Two-way, Listen-In Only or
Two-way voice comminucation in
Speech mode is two mins. During the 2-
min period, CTC-1041RV will emit two
beeps via the telephone handset to alert
the call recipient the remaining time of 20 &
10 sec. Pressing assigned DTMF key can
extend another 1-10 minute(s).
Command 47
Off-Set Time
After the Control Panel‘s power is supplied,
the time of the Check-in Report starts
calculating.
According to the setting of Off-Set Time,
the Control Panel will send Check-in
Report once, and then send report
according to the setting of Command 43
Test call.
Function
Selection
Result
(1) 1 Hour
(2) 2 Hour
(3) 3 Hour
(4)
4 Hour
(5)
8 Hour
(6) 12Hour
Factory default is set as (1) 1 Hour. When
the Off-Set Time is reset in programming
Mode, the time of the Off-Set period will
recalculate.
Off-Set time Report will be sent only once,
and then the Control Panel sends Check-in
Report according to setting of period test
call, unless the Control Panel restarts or
the Off-Set time is reset.
Command 49
Supervision
This function is not available for the digital
Scancom reporting method.
This option is used to enable system
Supervision function. Once enabled, CTC-
1041RV will be able to receive the check-
in signals from Wrist Pendants (WTR-) to
indicate their proper functioning.
Function
Selection
Result
(0) Disable
(1) 4 Days
(2) 5 Days
(3) 6 Days
(4)
7 Days
(5)
8 Days
(6) 9 Days
(7) 10 Days
(8) 30 Days
Factory default is set as (0) Disable. No
code is sent to Monitoring Center.
When the supervisory timer expires and no
supervision signal is received from WTR-,
the supervisory alarm reporting will be
made.
The reporting method for supervisory alarm
is the same as the emergency alarm. The
report will be sent based on your reporting