User's Manual

22
battery in the following cases:
Battery switch OFF
Battery not connected
Battery failure.
When the battery disconnection lasts for
10-15 mins, CTC-1041RV will report to the
Monitoring Center and the GREEN LED
flashes slowly.
If battery disconnection persists, CTC-
1041RV will emit 2 short beeps every hour.
The blinking status of RED LED can be
cleared by pressing the “RESET” button.
After the battery is restored and it lasts for
10~15min, CTC-1041RV will send Battery
Restore report to Monitoring Center and
the GREEN LED returns to steady ON.
4.1.6. Devices Low Battery
When CTC-1041RV receives a battery low
signal from a particular device, it will report
to the Monitoring Center and the GREEN
LED will flash rapidly until the fault
condition is cleared.
In addition, CTC-1041RV will emit 3 short
beeps every hour. Press the RESET
button on CTC-1041RV will stop the
warning beeps.
If any device Low Battery signal is
received again, the LED and warning
beeps will be performed accordingly.
Press the RESET button again to silent
the warning beeps.
After the faulty battery is replaced, CTC-
1041RV will immediately send Battery
Restore report to the Monitoring Center for
that particular device.
4.1.7. Automatic Check-in Report =
Periodic Test Call
When CTC-1041RV is programmed to
send a periodical check-in report, CTC-
1041RV will report to the Monitoring
Center accordingly.
The Periodic-Check-in Timer will be reset
whenever Programming Mode is entered.
4.1.8. Mobility Timer
In order to check the user’s well being, a
Mobility Timer can be set by using
Command #44.
If Mobility Timer is set as Enable, a
counting down period starts from:
Immediately after powering up CTC-
1041RV
Exit Programming Mode
After the pre-set Timer expires, CTC-
1041RV will emit a beep at every 5
minutes to notify the user for 30 minutes.
When the Mobility timer is not reset after
30 minutes, CTC-1041RV will send a
Mobility Timer Expired report to the
Monitoring Center every 30 minutes until
timer is reset.
Mobility Timer can be reset by pressing
RESET button once on CTC-1041RV or
whenever a movement is detected by PIR
Detector.
To disable the Mobility Timer function:
Set Command #44 to 0 (Disable), or,
Press and hold the RESET button on
CTC-1041RV for 16 seconds or
longer.
<
<
N
N
O
O
T
T
E
E
>
>
If no movement is detected during preset
mobility time, CTC-1041RV will send a CID
event code 641 with a fixed zone number 071
regardless of the zones the triggered motion
detectors occupy.
Disable the Mobility function in idle
mode:
Step 1: When the system is in Idle Mode,
press & hold the Reset Button for 16
seconds.
Step 2: During the 16-sec period, CTC-
1041RV will emit one short beep a
double beep continuous three short
beeps a long beep.
Step 3: Release the Reset Button when you
hear the last long beep; a short beep
will sound to indicate the mobility
function is disabled.
<
<
N
N
O
O
T
T
E
E
>
>
Please use Command #44 to enable the
Mobility timer again.